Provides
a constant voltage output for devices that are power
sensitive. |
 |
|
|
|
 |
Maintains a constant
14 volts output despite variations in voltage from
the vehicle electrical system. Ideal for operating
voltage sensitive equipment such as sensors,
computers, and communications systems. Permits
proper equipment operation despite inadequate
electrical system voltage, and protects equipment
from voltage surges of either polarity. |
 |
Provides a constant output voltage despite wiring
and connector losses, engine cranking loads, or
alternator failures. If the input voltage momentarily
drops below the minimum of 6 volts, the output
voltage will remain above 9 volts for at least 50ms
at full load current.
|
 |
Internal indicator LEDs verify proper operation.
|
 |
Efficient switching regulator design will not
overload the vehicle electrical system.
|
 |
Fully protected against low input voltage, voltage
spikes and transients, output short circuits, and
improper installation.
|
 |
Low profile enclosure comes complete with mounting
flanges for easy installation. Internal electronics
are sealed against humidity.
|
 |
Operates from -45 to +60 oC for reliable
operation in all weather conditions.
|
 |
Two year limited warranty.
|
 |
|
|
|
 |
Nominal output voltage: 14.0 +/- 0. 5 Volts
|
|
Transient input voltage suppresser (load dump
protection)
|
 |
Maximum output current: 1.2 Amp
|
|
Input - output lead reversal protection
|
 |
Minimum output current: 0 Amps
|
|
Output short circuit or overload current limit
circuit
|
 |
Minimum input voltage: 6.0 Volts
|
|
Dimensions: 6" long by 3.5" wide by
0.9" high
|
 |
Maximum input voltage: 18 Volts (normal operation)
|
|
Case material: Mounting plate: Sheet Aluminum
|
 |
80 Volts (short term transient exposure)
|
|
Top enclosure: Plastic
|
 |
Output noise and ripple: Less than 100 mVpeak to
peak
|
|
Enclosure rating: In cab mounting only
|
 |
Output short circuit duration: Indefinite
|
|
Connecting lead size: 18 Gauge by 8" long
|
 |
Operating temperature range: -45 oC to
+60 oC
|
|
Connecting lead color code: Red input lead, Yellow
output lead
|
 |
Fault tolerance protection: Low input voltage
lockout circuit
(less than 6.0 Volts)
|
|
|