Model 900D4S SeeLeveL II Single Channel - Overview

TOP

An electronic level gauge that provides precise levels of fluids in tanks up to 32' tall. Signal transmission format options include 4-20mA or 1-5V standards.
Model 900D4S SeeLeveL II Single Channel - Features

TOP

Patented microprocessor based digital system measures total fluid level with 1/4" resolution in tanks up to 32 feet high (longer lengths are in development).
Self powered system allows stand alone operation with no external power.
Large backlit LCD displays are easy to read in any lighting conditions and show product temperature, fluid level in inches, fluid volume and alarm status.
Battery condition can be shown at the push of a button.
Front panel keypad allows the display to be calibrated in the field, security codes control access to programming and allow the selection of which features are on or off.
Programmable 4-20mA or 1-5V analog outputs for both volume and temperature.
Polyethylene sender bar and float resist corrosion.
Based on a highly reliable design with over five years of production.
Temperature sensors are spaced every 16" in sender bar to provide average product temperature.
Designed for simple installation and servicing; system features modular design, fibre optic connection between sender bar and display (no electrician required), no external power requirements, and extensive diagnostic tools.
Operation from -45 to +60 oC ambient temperature, -45 to +90 oC product temperature.
One year limited warranty, competitive price.
Model 900D4S SeeLeveL II Single Channel - Specifications

TOP

Maximum number of tanks: One
Maximum tank height: 32 feet (9.75 m).
Principle of operation: Reed switches in sender bar are activated by magnets in the float, and are read by a microprocessor. Signal from the sender bar is transmitted to the display through plastic fibre optic cable, providing electrical isolation for hazardous environments.
Resolution: 1/4 inch (6 mm).
Accuracy: ± 1/8 inch (3 mm), temperature drift is zero.
Specific gravity sensitivity: Float sinks one inch (25 mm) in water.
Hysteresis: 1/16 inch (1.5 mm) (Difference between reading with float rising and reading with float falling. Eliminates display flicker.)
Maximum fibre optic length: 200 feet (60 m). Fibre can simplay be cut with a knife, no special tools required.
Ambient temperature range: -45 to +60 °C, product temperature range is -45 to +90 °C.
Battery lifetime: 5 years continuous operation for both sender bar and LCD display. Sender bar powered by replaceable lithium battery module. Display powered by four alkaline "AA" cells.
Display type: 0.5" LCD with LED backlight.
Display temperature drift: 0
Alarms: Four alarms, each consisting of a transistor conducting to ground when the alarm is "on". Each transistor has a rating of 100 mA at 24 volts DC. An optional relay interface is available for 115 VAC applications. Alarms default "off" if the signal from the sender bar is corrupted or lost.  Alarm temperature drift is zero.
Remote communications: Two 4-20 mA two wire outputs for fluid volume and temperature, optically isolated, 12 to 24 volt loop voltage required.
Or two 1-5V three wire outputs for fluid volume and temperature, optically isolated, 12 to 24 volt loop voltage required.
4-20 mA output temp. drift: ± 20ppm/°C
Temperature sensors: Sensors located inside the sender bar, spaced 16" apart. Temperature measurement range is from -40°C to +99°C; accuracy is ±2°C worst case.
Power requirements: Display/Sender Bar: None (operate from internal batteries). Alarms: External indicators must provide their own power. Relay interface requires 115 VAC.  4-20mA and 1-5V transmitters must be externally powered.
Display enclosure: NEMA 4 rated fibreglass enclosure, 6 inches wide by 8 inches high by 4 inches deep.
Float construction: Cylindrical, approximately 7.25 inches diameter by 4.5 inches high. Float material is polyethylene.
Bar construction: Nominal 1/2" polyethylene pipe houses reed switches and temperature sensors.
Fitting requirements: Sender bar is held in place at the top with a one inch compression fitting, requires a one inch female NPT thread in the tank top. At tank bottom either a weighted anchor or a weld in anchor can be used.
Diagnostics: Display shows if signal from sender bar is corrupted or lost.
Model 900D4 SeeLeveL II Four Channel -  Programming Note

TOP

The 900D4S monitor has several programming options, all of which are field programmable at any time from the front panel keypad. Programmable security codes prevent unauthorized access and controls which gauge features are active. All memories are retained even if the batteries are dead or removed.
For upright tanks with a linear calibration (equal volume per inch of depth throughout the tank) the volume reading can be calibrated by entering a single number for volume per inch of depth. For tanks on their side with a nonlinear calibration, the volume reading can be calibrated by entering a table of values for inches of depth verses volume. The volume offset can be set to specify where the zero volume point is in the tank. The temperature can be set to read in °F or °C.
The alarms can be set independently to any point in the tank, and can be set to turn on or off as the fluid level rises. The full scale of the volume 4-20mA or 1-5V outputs are calibrated from the front keypad, there are no analog controls to adjust.
Home > Stationary Applications > Model 900D4S

If you need assistance, feel welcome to contact us.

Home | About Us | Contact Us | Site Map | Privacy Policy
Transport (Tech Support| Stationary (Tech Support| RV (Tech Support| Dealers & Distributors

 

Canada
Toll Free: 1-800-617-7384
 Email:
info@GarnetInstruments.com

U.S.A.
Toll Free: 1-877-668-7813
Email:
sales@RVGauge.com         

  

© 2004 Garnet Instruments Ltd.