Enhance Your SeeLeveL System with Overfill Protection
Key Features & Benefits
Model 815-UHP / 815-UHPH
The SpillStop Ultra™ Alarm Controller works in conjunction with the SeeLeveL Special™, SeeLeveL Flair™, and SeeLeveL Octane™ to provide an audible warning horn, high-level pump shutdowns, and hose protection. This product increases safety and prevents spill-related costs. The SeeLeveL Junction Box™ can be added to simplify wiring.
- Provides automated control of PTO or hydraulic driven pumps for overfill protection during loading.
- Prevents spills and damage due to blown hoses by shutting down loading if excessive hose pressure is detected.
- Monitors the wiring from the gauge to the controller for open and short circuits.
- Defaults to shut down condition if malfuctioning
- Operates from standard 12 VDC truck power
- Each SpillStop accommodates one compartment using alarm points from one SeeLeveL™ gauge.
Operation Overview
Under normal loading conditions, the SpillStop Ultra™ is wired with an external warning horn and the loading pump. When the tank is being filled, the SpillStop™ will activate the warning horn and first-level shutdown at the Alarm 2 set point pre-programmed in the 808P2. The Alarm 2 set point is used to alert the operator that the tank is nearing full. Once Alarm 2 is activated, the horn alarm will sound AND the pump will shut off. At this point, the operator can press the bypass button on the SpillStop™ to silence the horn and regain the pump to clear the hose. However, if the operator continues to load to alarm 1 (high-level shutdown)also pre-programmed in the 808P2, the pump will shut off and will not power up again until the tank level drops below the alarm 1 set point. Alarm 1 is used as a high-level emergency shutdown and cannot be bypassed. As an added feature, the SpillStop™ can be wired to a pressure switch on the load line. If pressure on the load line spikes due to a valve being closed, the SpillStop will immediately shut down the pump, preventing hose blow-out.
If loading begins before a ground connection is established, or if the ground connection is lost during operation, a warning horn will sound. If the connection is not made or restored within the preset time, the final alarm will activate. After loading is complete, shut down the loading system and disconnect the ground clamps.